barrel hot water boiler

Product Name: barrel hot water boiler
Parameter:[ Parameter table ]

Introduction

1.the object adopts new three returning wet-backward form structure, big
  boiler bladder and screw to strengthen hearth radiation absorbing volume.
  The two and three returning wet-backward form structure adopts the design of   equal resistance,   which can reduce the machine volume and the weight,
  decrease not only the steel consumption, but also user's energy consumption.

2.the mach ine operates in the high automatic degree, hot water machine has
  the some certain equipment, including automatically swepting when the
  procedure start up, electronic self-ignition, automatic combustion, wind
  oil/gas automatic proportion and Flameout protection extinguishing
  protection, and can bring out some certain functions, including the dialogue   between human and   machine, remote control, abnormal failure alarm signal,
  automatic fault diagnosis and operation on regular hour and temperature in
  24 hours.

3. The machine matches the advanced combustion turbine which burns completely,    save energy, has    environmentally responsibility, and can be installed
   and operated in the scenic spots. It can eliminate the possibility
   of explosion accidents, operates safely and resolve users¡¯ actual
   difficulties.

4.Burning harmlessly, big bladder is adopted to decrease the capability
  strength and escape volume of nitrogen oxides, and completely meet the
  national environmental protection standard.

5.The machine, with smaller footprints, can be installed the roof, first floor   building, basement or room for specialized equipment.

6.Whole-Link area design is convenient to disassemble and preserve,
  which dominate in the home market.

¡¡

 Parameters£¨1£©

 Remarks: low level heat volume of fuel in the table is calculated according to the following:
 Light diesel oil: 10200kcal/kg Heavy oil: 10000kcal/kg gas: 8000kcal/kg Liquefied gas: 24000kcal/kg
 2 when the fuel heat value and chemical component changes, the Parameter in the table will changes.

type CWNS
0.12-95/70-Y(Q)
CWNS
0.174-95/70-Y(Q)
CWNS
0.23-95/70-Y(Q)
CWNS
0.35-95/70-Y9(Q)
CWNS
0.4795/70-Y(Q)
CWNS
0.58-95/70-Y(Q)
 Parameter
 Output heat £¨1X10KCAL/H£© 10 15 20 30 40 50
£¨KW£© 116 175 262 350 465 581
 Volume of producing hot  water  (kg/h)¡÷t=30¡æ 3300 5000 6600 10000 13300 16600
 Applicable fuel Light diesel oil, Heavy oil, gas, Liquefied gas
Fuel consumption  Light diesel oil
 £¨kg/h£©
10.9 16.4 21.9 32.7 43 53.7
 Heavy oil£¨kg/h£© 11.2 16.8 22.4 33.5 44 54.9
 gas£¨M3 /H£© 14 21 28.1 41.9 55 68.7
 Liquefied gas
£¨M3 /H£©
4.7 7.1 9.4 13.6 18.3 22.9
 Heat efficiency £¨%£© 91%-93%
 Power  Power expenditure  efficiency£¨KW£© 0.15 0.15 0.45 0.75 1.1 1.1
 voltage£¨V£© 220/380 50HZ
weight£¨KG£© 680 720 1230 1430 1620 1990
Water volume£¨L£© 315 415 520 680 1056 1250
 Outline size
 £¨mm£©
L 1550 1650 1720 2080 2530 2760
W 800 800 880 880 1180 1250
H 1350 1450 1610 1610 1885 1968

 Parameters£¨2£©      
type CWNS
0.7-95/70-Y(Q)
CWNS
0.93-95/70-Y(Q)
CWNS
1.163-95/70-Y(Q)
CWNS
1.4-95/70-Y9(Q)
CWNS
1.75/70-Y(Q)
 
 Parameter
  Output heat £¨1X10KCAL/H£© 60 80 100 120 150  
£¨KW£© 700 930 1163 1400 1750  
 Volume of producing hot  water(kg/h)¡÷t=30¡æ 20000 26600 33000 40000 50000  
 Applicable fuel Light diesel oil, Heavy oil, gas, Liquefied gas
 Fuel consumption  Light diesel oil
 £¨kg/h£©
64.4 85.9 106.1 127.4 159.2  
 Heavy oil£¨kg/h£© 65.9 87.9 108.7 130.4 163  
 gas£¨M3 /H£© 82.4 109.9 135.8 163 203.8  
 Liquefied gas
 £¨M3 /H£©
27.5 36.6 45.3 54.3 67.9  
 Heat efficiency£¨%£© 91%-93%
 Power  Power expenditure  efficiency£¨KW£© 1.5 1.5 3 4 4  
 voltage£¨V£© 220/380 50HZ
weight£¨KG£© 2290 2460 2650 4860 5260  
Water volume£¨L£© 1380 1675 1956 2365 2850  
 Outline size
 £¨mm£©
L 2760 2980 3300 3300 3580  
W 1250 1500 1550 1658 1700  
H 1968 1990 1990 1990 2140  

[ close ]